Air-Cooled Centrifugal Chillers for Mission-Critical Cooling

Deliver mission-critical cooling without the complexity of conventional oil systems. Gradian’s air-cooled centrifugal chiller combines 550 tons of cooling capacity with oil-free Aero-Lift compressor technology, rapid restart, and flexible chilled water operation for demanding data center environments.

  • 550 Tons Cooling Capacity

  • Sub 1 Minute Restart

  • Up to EWT 55C and LWT 45C

  • Oil-Free Aero-Lift™ Centrifugal Compressors

Key Features

What makes a Gradian Centrifugal Chiller?

Oil-Free Aero-Lift™ Compressor Technology

Copeland oil-free centrifugal compressors self-levitate the shaft without oil lubrication, electromagnetic bearings, proximity sensors, or active bearing controls, eliminating an entire category of mechanical complexity and its associated maintenance.

Rapid Restart

Get cooling back online, fast. Minimize downtime and utility disruptions with a rapid restart of less than 1 minute.

Wide Chilled Water Temperature Range

Supports chilled water temperatures up to 90°F, along with high-lift, 2-stage compressor technology that maintains performance at full load or low turndown even under demanding ambient conditions.

Technical specifications

PerformanceCommon to all sizes
Cooling Capacity550 Tons
RefrigerantR-513A
Circuits / Compressors2 circuits, 2 compressors per circuit (4 total)
Capacity ModulationVariable Frequency Drive (VFD)
Turndown5:1
Evaporator TypeShell-and-Tube, Flooded
Condenser CoilsMicro-Channel
Controls Tolerance±1°F
Electrical & ControlsCommon to all sizes
Power Supply460V / 3-Phase / 60Hz — SCCR 65kA
Power Consumption466 kW
ControllerCarel pco5
CommunicationBACnet IP/MS-TP, Modbus TCP/IP and RTU
CompatibilityCommon to all sizes
Dimensions633"L x 95"W x 100"H
Weight (Shipping / Operating)224,880 lbs / 236,120 lbs

Downloads

Cut Water Out of the Equation

Water availability is increasingly deciding where AI infrastructure is being built. Air-cooled architecture removes cooling towers, condenser-water pumps, and water treatment from the equation entirely. Now the site's water situation stops being part of the cooling conversation.

  • Air-Cooled Condensers - Reject heat directly to air, no cooling tower or evaporative process required.

  • No Water Treatment System - Remove the chemical treatment and upkeep a cooling tower requires.

  • Unlock Sites Water Constraints Would Otherwise Rule Out - Build where water permitting, availability, or sustainability requirements would limit a water-cooled plant.

Less Maintenance. More Uptime

Mission-critical cooling shouldn't come with another maintenance-intensive piece of rotating equipment. Oil-free Aero-Lift™ compressor technology removes the oil system entirely,  without adding the magnetic-bearing sensing and backup hardware that other chillers require.

  • No Oil System - Eliminate oil pumps, filters, separators, and routine oil service.

  • Improved Reliability - No magnetic-bearing sensing, redundant backup bearings, or capacitor to manage.

  • Independently Serviceable Components - Service compressors, drive, and controls independently, reducing downtime and reliance on specialized factory technicians.

Get Back Online in Under a Minute

When utility power drops and generators take over, you need cooling infrastructure that gets to work fast. Sub-1-minute restart gets cooling capacity back online while the rest of the facility is still stabilizing.

  • Sub-1-Minute Restart - Restore cooling quickly following a utility or generator event.

  • Reduced Recovery Risk - Shorten the window IT load runs without full cooling capacity.

  • Built for Mission-Critical Operation - Designed for environments where even short interruptions carry real risk.

FAQs

Questions, answered.

  • An oil-free centrifugal chiller removes the conventional oil-lubrication system entirely. Gradian Air-Cooled Centrifugal Chillers use Aero-Lift™ compressor technology, where the compressor shaft self-levitates without oil, electromagnetic bearings, or active bearing controls — eliminating oil pumps, filters, separators, and their associated maintenance.